Factory settings Proline Prowirl 73
180 Endress+Hauser
12 Factory settings
12.1 SI units (not for USA and Canada)
12.1.1 Units of temperature, density, length, spec. enthalpy
12.1.2 Language
12.1.3 Unit totalizer 1 + 2
12.1.4 Switch-on point and switch-off point
The factory settings in the table are given in the dm³/s unit. If another unit is selected in the UNIT
VOLUME FLOW function (ä 102), the corresponding value is converted and displayed in the
selected unit.
Unit Unit
Temperature °C Length mm
Density kg/m³ Specific enthalpy kWh/kg
Country Language Country Language
Australia English Luxembourg Francais
Austria Deutsch Malaysia English
Belgium English The Netherlands Nederlands
Czechia Cesky Norway Norsk
Denmark English Poland Polski
England English Portugal Portugues
Finland Suomi Singapore English
France Francais South Africa English
Germany Deutsch Spain Espanol
Hong Kong English Sweden Svenska
Hungary English Switzerland Deutsch
India English Thailand English
Italy Italiano Other countries English
Flow Unit Flow Unit
Volume flow Corrected volume flow Nm³/m
Calculated mass flow kg Heat flow kWh
Nominal diameter DN Gas Liquid
DIN[mm] ANSI[inch] On-value
[dm
/s]
Off-value
[dm
/s]
On-value
[dm
/s]
Off-value
[dm
/s]
15 ½" 7.7 6.3 1.5 1.2
25 1" 38 31 4.6 3.8
40 1½" 94 77 11 9.2
50 2" 160 130 19 15
80 3" 350 290 42 35
100 4" 610 500 73 60
150 6" 1400 1100 170 140
200 8" 2700 2200 320 260
250 10" 4200 3400 500 410
300 12" 6000 4900 720 590