11.19 HART INPUT
Function description, HART INPUT group
Prowirl can read in an external pressure, temperature or density value with the HART INPUT function. The external
value can be read in at a rate of up to three values per second. For a detailed connection diagram, see ä 30
Prerequisite
• This mode is not possible for transmitters that are HART-enabled but NOT burst-enabled (e.g. iTemp 162).
• The HART INPUT group is only available if OFF was selected in the BURST MODE function (ä 138).
HART INPUT Description
For selecting the input variable.
Options
OFF
PRESSURE
TEMPERATURE
DENSITY
TEMPERATURE 72
PRESSURE 72
DENSITY 72
Factory setting
OFF
!
Note!
If you are using Prowirl 73 electronics on a Prowirl 72 meter body and DSC sensor,
select the PRESSURE 72, TEMPERATURE 72 or DENSITY 72 setting. With these
options, Prowirl 73 fluid temperature measurement is ignored.
Select the option depending on the sensor used or the setting in SELECT FLUID
(ä 143):
Settings other than those indicated here are NOT possible in conjunction with the
SELECT FLUID (ä 143) function.
1)
The internal temperature measurement is used to compensate the K-factor.
2)
The external temperature measurement is used to compensate the K-factor.
3)
If a density value is read in, it is not possible to output the heat flow.
Prowirl 73 - sensor
:
Prowirl 72 - sensor:
SELECT FLUID DENSITY
PRES-
SURE
TEMPER-
ATURE
SELEC-
TION
WATER, USER DEFINED LIQUID X – – DENSITY
SATURATED STEAM,
SUPERHEATED STEAM,
COMPRESSED AIR, NATURAL
GAS AGA NX-19, CARBON
DIOXIDE, NITROGEN, OXYGEN
XX–
PRESSURE
or
DENSITY
SATURATED STEAM DELTA HEAT,
WATER DELTA HEAT
––X
TEMPERA-
TURE
SELECT FLUID DEN-
SITY***
PRESSURE TEMPERA-
TURE
SELECTION
SATURATED STEAM
X
X (no tem-
perature)
X** (no
pressure)
DENSITY 72,
TEMPERATURE
72 or PRESSURE
72
WATER, USER DEFINED
LIQUID X – X**
DENSITY 72 or
TEMPERA-
TURE 72
SUPERHEATED STEAM,
COMPRESSED AIR,
CARBON DIOXIDE,
NITROGEN, OXYGEN,
REAL GAS, GAS MIXTURE
X Cannot be selected