Proline Prowirl 73 Technical data
Endress+Hauser 79
!
Note!
By using the selection and planning program "Applicator", you can determine the exact values for
the fluid you use. You can obtain the Applicator from your Endress+Hauser sales center or on the
Internet under www.applicator.com.
K-factor range:
The table is used for orientation purposes. The range in which the K-factor can be is indicated for
individual nominal diameters and designs.
Standard version: DN 50 (2") to 300 (12")
R Style:
DN 80 (3") > DN 50 (2")
Nominal diameters larger than DN 80 (3")
S Style:
DN 100 (4") >> DN 50 (2")
Nominal diameters larger than DN 100 (4")
120 m/s (394 ft/s) or Mach 0.3
(depending on which value is smaller)
Calibrated range: up to 75 m/s (246 ft/s)
Nominal diameter v
max
Nominal diameter K-factor range [pul./dm³]
DIN ANSI 73F 73W
DN 15 ½" 390 to 450 245 to 280
DN 25 1" 70 to 85 48 to 55
DN 40 1½" 18 to 22 14 to 17
DN 50 2" 8 to 11 6 to 8
DN 80 3" 2.5 to 3.2 1.9 to 2.4
DN 100 4" 1.1 to 1.4 0.9 to 1.1
DN 150 6" 0.3 to 0.4 0.27 to 0.32
DN 200 8" 0.1266 to 0.1400
DN 250 10" 0.0677 to 0.0748
DN 300 12" 0.0364 to 0.0402