10 Technical data Promag 53 PROFIBUS-DP/-PA
134 Endress+Hauser
Process
Medium temperature
range
The permissible fluid temperature depends on the lining of the measuring
tube:
Promag W
0...+80 °C in the case of hard rubber (DN 65...2000)
–20...+70 °C in the case of polyurethane (DN 25...2000)
Promag P
–40...+130 °C in the case of PTFE (DN 15...600), restrictions
→ see diagrams
–20...+180 °C in the case of PFA (DN 25...200), restrictions
→ see diagrams
Compact version Promag P (PFA or PTFE lining)
T
A
= ambient temperature, T
F
= fluid temperature
HT = high-temperature version, with insulation
Remote version Promag P (PFA or PTFE lining)
T
A
= ambient temperature, T
F
= fluid temperature
HT = high-temperature version, with insulation
0
0
-20 20
20
40
60
T
A
[°C]
40 60 80
T
F
[°C]
100 120 140 160 180
HT
PTFE
PFA
F06-5xPxxxxx-05-xx-xx-xx-000
0
0
-20 20
20
40
60
T
A
[°C]
40 60 80
T
F
[°C]
100 120 140 160 180
HT
PTFE
PFA
F06-xxPxxxxx-05-xx-xx-xx-000