10 Technical data Promag 53 PROFIBUS-DP/-PA
166 Endress+Hauser
Process connections orderable only as accessories (with O-ring seal, DN 2...25)
Coupling SMS 1145
1.4404 / 316L
5*H**-5***********
Sensor Pipe di G L H x B
DN [mm] Coupling [inch] [mm] [mm] [mm] [mm]
1" (25 ANSI) 1" 22.1 Rd 40 x 1/6" 30.8 70 x 52
Fitting length = (2 x L) + 86 mm
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 156)
and process connection (di) into account.
F06-xxHxxxxx-06-09-07-xx-026
External pipe thread NPT
1.4404 / 316L
DKH**-GD**
Sensor Pipe di G L S H x B
DN [mm]
Internal thread
[inch]
[mm] [inch] [mm] [mm] [mm]
2...8 NPT 3/8" 10 3/8" 50 15.5 60 x 42
15 NPT 1/2" 16 1/2" 50 20.0 60 x 42
1" (25 ANSI) NPT 1" 25 1" 55 25.0 70 x 52
Fitting length = (2 x L) + 86 mm
G
di
L
H x B
S
F06-xxHxxxxx-06-09-07-xx-025
Internal pipe thread NPT
1.4404 / 316L
DKH**-GC**
Sensor Pipe di G D L S H x B
DN [mm]
External thread
[inch]
[mm] [inch] [mm] [mm] [mm] [mm]
2...8 NPT 3/8" 8,9 3/8" 22 45 13 60 x 42
15 NPT 1/2" 16,0 1/2" 27 45 14 60 x 42
1" (25 ANSI) NPT 1" 27,2 1" 40 49 17 70 x 52
Fitting length = (2 x L) + 86 mm
D
G
di
L
H x B
S
F06-xxHxxxxx-06-09-07-xx-027

Table of Contents