Promag 53 PROFIBUS-DP/-PA 10 Technical data
Endress+Hauser 167
Process connections orderable only as accessories (with gasket seal)
Ground rings (accessories)
Tri-clamp for ODT
1.4404 / 316L
DKH**-HF***
Sensor Pipe di G L H x B
DN [mm] Tri-Clamp [mm] [mm] [mm] [mm]
15 Tube 25.4 x 1.5
(ODT; 1")
22.1 50.4 28.5 60 x 42
Fitting length = (2 x L) + 86 mm
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 156)
and process connection (di) into account.
F06-xxHxxxxx-06-09-07-xx-018
Grounding ring
1.4435 (316L) tantalum,
platinum or Alloy C-22
DK5HR ****
Sensor di D B C
DN [mm] [mm] [mm] [mm] [mm]
2...8 9.0 33.9 22.0 17.6
15 16.0 33.9 29.0 24.6
25 (DIN) 22.6 43.9 36.5 31.2
1" (25 ANSI) 26.0 43.9 39.0 34.6
Ø C
Ø di
Ø B
Ø D
1.9
4.5
3.4
0.5
3.5
Ø C
Ø di
Ø B
Ø D
1.9
4.5
3.4
0.5
3.5
F06-xxHxxxxx-06-09-07-xx-030