Document number: ED.03783.00.001.ENG rev 4 Page 118 of 153
3. Click AD-min inside the Set AD values group
4. Click AD-max inside the Set AD values group
5. Click File in the menu bar; then click save and exit
Alternatively, for the JS500, it is possible to use the factory settings of a specific unit. Then there
is no need to extend and retract the cylinders.
1. Select a unit
2. Use the drop down menu to select the correct unit number for the unit position in the
setup used for a specific job
3. Click File in the menu bar; then click save and exit
To enter the values for which you want an alarm raised, proceed as follows:
1. Select a unit
2. Enter the minimal and maximum values in the field Alarm values
3. Click File in the menu bar; then click save and exit
NB
Calibration is always required when a stroke sensor has been replaced.
This function has to be executed by a specialist.
Caution
No safety precautions are active during calibration.
During calibration the movements of the main jacks are not synchronised; be
aware that the jacks won’t extend / retract equally.
Hazard
For the JS500, the calibration should be executed without the End Barrel in the
system or with the End Barrel locked by the mini Jacks. When failing to follow
this requirement the system will be damaged and causes potential hazards to
personnel.