8 Solve problems
This chapter describes localization and solving of problems.
A main problem localization procedure is given.
A list of possible problems is given, together with causes and possible solutions.
8.1 Main problem localization procedure
In case of anomalies proceed as follows to solve the problem:
1. Was any Emergency stop button pressed?
2. Is the communication between laptop and the system broken?
Use Communication / Connect on the HMI to re-establish the connection.
3. Is any error indicator lit on one of the HPU’s?
4. Is any error message visible on the HMI of the laptop?
5. Are there are mechanical blockades?
6. Is any hydraulic leakage is visible?
7. Are any fuses tripped?
Check the fuses inside the electro cabinets.
8. Call Enerpac of you need assistance.
8.2 List of problems and solutions
The table below lists a number of errors and problems which may appear during the use of the
system, together with possible causes and solutions.
8.2.1 Main problems
Symptom
Possible cause
What to do…
Main problems
A unit does not move while the
others do
The unit is not selected
Select the unit on the HMI