Document number: ED.03783.00.001.ENG rev 4 Page 122 of 153
Not all Mini Jacks Nr 1 are In or Out"
Check Positions, Proximity switches and cables
from Mini Jack Nr 1
Not all Mini Jacks Nr 2 are In or Out"
Check Positions, Proximity switches and cables
from Mini Jack Nr 2"
Not all Mini Jacks Nr 3 are In or Out"
Check Positions, Proximity switches and cables
from Mini Jack Nr 3
Not all Mini Jacks Nr 4 are In or Out"
Check Positions, Proximity switches and cables
from Mini Jack Nr 4
Cilinder 1 Overloaded, Max = 1840kN
Check Load and / or Pressure sensors Cilinder 1
Cilinder 2 Overloaded, Max = 1840kN
Check Load and / or Pressure sensors Cilinder 2
Cilinder 3 Overloaded, Max = 1840kN
Check Load and / or Pressure sensors Cilinder 3
Cilinder 4 Overloaded, Max = 1840kN"
Check Load and / or Pressure sensors Cilinder 4
Negative Load in system of more than -
40kN"
Check Positions and Mini Jacks.
Check Load and Manual Overload setting or
Expected Load Setting Manual overload is Max
120% Expected Load
Check Load and Automatic Overload setting or
Expected Load Setting Automaticl overload is Max
110% Expected Load
Check oil filter for dirt and/or replace filter
File Calibrations_Settings.Dat not found
File Settings_Settings.Dat not found
Hazard
Performing repairs on the system may cause dangerous effects when not
executed by well-skilled personnel.
NB
The tables are intended as a first aid kit. Contact Enerpac if you need
assistance.