Some of the maintenance jobs need extra directions; those directions are given in the table below.
2. Hydraulic connections
2.1. Pipes, hoses and
brackets
Check on oil leakage and damages
O/EE
x
Check if the couplings are tightened well.
O/EE
x
x
Replace all seals within the piping (Waldform)
EE
x
Replace all hoses
EE
x
Replace all plastic brackets
EE
x
2.2. Couplings and
quick-screw
couplings
Check on oil leakage and damages
O/EE
x
Check if the couplings are tightened well.
O/EE
x
x
Replace all seals of the couplings
EE
x
Replace fast couplings and screw couplings
EE
x
2.3. Gauges,
measurement
sensors
Check on damages
O/EE
x
Check the tightening bolts, nuts and components
O/EE
x
x
Replace all seals
EE
x
Replace all gauges
EE
x
3. Housing
3.1. Common
Check on damages and paint
O/EE
x
Check if the bolts are still tightened
O/EE
x
x
Replace all seals, door seals and inspection hatches
EE
x
Grease the hinges and locks
O/EE
x
Replace engine feet
EE
x
4. Cylinders
4.1. Common
Check on leakages
O/EE
x
Check if the bolts are still tightened
O/EE
x
x
Replace all seals
EE
x
Grease the bearings
EE
x

Table of Contents