Temperatures, both for units and trolleys
Operating temperature of the machine
Min
-20°C
Max
+50°C
Temperature of the hydraulic oil
Min at start up
-20°C
Min operation
-20°C
Max in operation
+70°C
Storage temperature of the machine
Min
-25°C
Max
+60°C
Storage temperature of the smartbox
Min
-25°C
Max
+60°C
Hydraulic oil
Type
Shell Tellus S4 VE 46
Purity
class 10 of NAS 1638
class 21/19/16 of ISO DIS 4406
Noise pressure, both for units and trolleys
Measured at ear height at nominal loading one metre away from any Unit’s
electric motor. (The C-weighted instantaneous sound pressure of 130 dB is
never exceeded)
72 dB(A)
Caution
There is a risk of ice accretion at temperatures below 0ºC.
If ice has accreted on machine components, they cannot be used since they
may lock up.
Consult Enerpac if you want to apply the system by other temperatures.