Troubleshooting Status Display (AcuLaser C1900) 130
ERROR CODE: E033 “TRANSPARENCY DETECTION SENSOR PROBLEM”
 Detection Timing
Transparency is not detected.
 Solution
 Electric parts which can cause the trouble:
• OHP Sensor (PC3A)
• Engine Board (PWB-A)
EEPROM ERROR
·ERROR CODE: E041 “MAIN UNIT MEMORY COUNTER PROBLEM”
·ERROR CODE: E042 “MAIN UNIT MEMORY DATA PROBLEM”
·ERROR CODE: E043 “MAIN UNIT MEMORY ACCESS PROBLEM”
·ERROR CODE: E044 
“MAIN UNIT MEMORY INSTALLATION PROBLEM”
 <Detection Timing>
EEPROM error detection
 Solution
 Electric parts which can cause the trouble:
• EEPROM
• Engine Board (PWB-A)
ERROR CODE: E998 “ENGINE COMMUNICATION ERROR”
 Detection Timing
Any error has occurred in communication through the video interfere between the 
Main Board and the Engine Board.
 Solution
 Electric parts which can cause the trouble:
• Main Board (C485MAIN)
• Engine Board (PWB-A)
Table 3-16.
Step Action Refer to
WARNING DIAGRAM
Control Signal
1 Check the operation of PC3A. p.162 PC3_REM
2 Replace the PWB-A. - -
Table 3-17.
Step Action Refer to
WARNING DIAGRAM
Control Signal
1 Replace the EEPROM. - -
2 Replace the PWB-A. - -
Table 3-18.
Step Action Refer to
WARNING DIAGRAM
Control Signal
1 Check the connection between Main 
Board and Engine Board.
--
2 Replace the Main Board (C485MAIN). - -
3 Replace the Engine Board (PWB-A). - -