EPSON AcuLaser C1900/AcuLaser C900 Revision B
Product Description Basic Specifications 35
1.2.6 Storage and Transport Environments of the
Packaged Printer Main Unit and Optional Products
NOTE: Including Bundled Consumables
Temperature and Humidity Conditions
Note *1: 35 ~ 55 °C when the DEVELOPER cartridges and photoconductor unit are
uninstalled.
*2: Condensation must be avoided.
Barometric Pressure for Storage (Altitude):741 ~ 1013 hPa
NOTE:
1 613 ~ 1013 hPa when the DEVELOPER cartridges and
photoconductor unit are uninstalled.
Dropping : No damage must occur for packaged products in dropping from
52 cm height, and in 1 corner, 3 edges, 6 sides of direction.
Compliant with the EPSON transport assessment standard (T-
AE05-001-001).
Vibration : Must conform to the JIS Z0200-1999 level 1
Compression : Refer to Packing Specifications.
Size : Refer to Packing Specifications.
Weight : Refer to Packing Specifications.
Loading : Refer to Packing Specifications.
Pallet Size : Refer to Packing Specifications.
1.2.7 Electrical Feature
In the following items, all options are excluded.
Fast Transient / Burst (AC Line Noise)
The following conditions shall be met in the “IEC61000-4-4” compliant evaluation.
1kV : No error excepting minor dot errors.
1.8kV : No Component damaged.
Instantaneous Outages
DIP 100% of instantaneous outages (at rated voltage - 10%) for 1-cycle
No deterioration in the printing quality.
The following condition shall be met in the “IEC61000-4-11” compliant
evaluation.
95% lowered 0.5 cycle : No error excepting minor dot errors.
30% lowered 25 cycle : No component damaged.
95% lowered 250 cycle : No component damaged.
Resistance to Static Electricity
The following condition shall be met in the “IEC61000-4-2” compliant evaluation.
Contact discharge 8 kV : No error in any devices.
Discharge into the air 15 kV : No error in any devices.
Inrush Current
1/2-cycle : 50 A or less (0-peak) (At 23
°
C or higher)
<Reference: Actually measured value including heater inrush>
100V: 1/2 cycle 88.0 A (0-peak)
120V: 1/2 cycle 66.0 A (0-peak)
220V: 1/2 cycle 35.6 A (0-peak)
240V: 1/2 cycle 38.0 A (0-peak)
(
By cold start at 23°C
)
Insulation Resistance
10 M or more
Table 1-19.
Temperature Humidity Warranty period
Normal Conditions 0 to 35 °C 30 to 85% RH
*2
18 month after production
Severe Conditions High temperature:
35 ~ 40 °C
*1
Low temperature:
-20 ~ 0 °C
High humidity:
85 ~ 95% RH
*2
Low humidity:
10 ~ 30% RH
*2
1/30 of 18 months