EPSON AcuLaser C1900/AcuLaser C900 Revision B
Product Description Basic Specifications 36
Withstand Voltage
Breakdown must not occur when the voltages shown in the table below are applied for 
one minute.
 Leak Current
100 V: 0.25 mA or less 
*1
120 V: 3.5 mA or less
220 V: 3.5 mA or less
NOTE: *1: The measuring method is compliant with “PC-11-1988”.
1.2.8  Compatible Standard
 Safety Standard
 Safety Standard (Laser Transmission)
<Reference>
• Laser diode
Wavelength (Min. ~ Max.:)) 770 ~ 795 nm
Max. output rating: 5 mW
 EMI
 Electrical higher harmonics wave
 Complies with the Higher Harmonics Restraint Guidelines
 100 V: Compliant with JBMG-3 (1995)
 200 V: Compliant with EN61000-3-2 Class A
 Electrical Power Consumption
Conforms to the International Energy Star Program standards
Table 1-20.  Withstand Voltage
Across primary and chassis
For 100/120 V system models AC1,000 V
For 220 V system models AC1,500 V
100 V/120 V UL1950 3rd Edition 
CSA C22.2 No.950-95 3rd
200 V system IEC60950 2nd + Amd 1, 2, 3, 4 
EN60950: 2nd + Amd 1, 2, 3, 4, 11 (1997)
Annex ZB, ZC
120 V FDA21CFR Chapter 1 Subchapter J Part1040
200 V system EN60825-1 + A11
100 V VCCI Class B J55022 Class B
120 V FCC 47CFR Part 15 Subpart B, Class B 
CNS13483 Class B 
ICES-003 Issue 3 Class B (C108.8-M1983)
200 V system EN 55022 Class B 