EPSON AcuLaser C9200N Revision D
Troubleshooting Service Call Error 123
Confidential
E610: 1ST IMAGE TRANSFER ATVC (COLOR) FAILURE
E611: 1ST IMAGE TRANSFER ATVC (K) FAILURE
Ì
E612: 2ND IMAGE TRANSFER ATVC FAILURE
Relevant Electrical Parts
Transfer Belt Unit
Transfer Roller
High Voltage Unit
Step Action
Connection Diagram
Control Signal
Location
(electrical parts)
1 Check if the Transfer Roller and
Transfer Belt are dirty and correct as
necessary.
--- ---
2 Change High Voltage Unit (p.230) --- ---
3 Change Transfer Belt Unit (p.162) --- ---
Relevant Electrical Parts
Transfer Belt Unit High Voltage Unit
Step Action
Connection Diagram
Control Signal
Location
(electrical parts)
1 Check if the Transfer Roller and
Transfer Belt are dirty and correct as
necessary.
--- ---
2 Change High Voltage Unit (p.230) --- ---
3 Change Transfer Belt Unit (p.162) --- ---
Relevant Electrical Parts
Transfer Belt Unit
2nd Transfer Roller
High Voltage Unit
Step Action
Connection Diagram
Control Signal
Location
(electrical parts)
1 Check if the Transfer Roller and
Transfer Belt are dirty and correct as
necessary.
--- ---
2 Check that the 2nd Transfer Roller is
properly installed and correct as
necessary.
--- ---
3 Change 2nd Transfer Roller. (p.169) --- ---
4 Change High Voltage Unit. (p.230) --- ---