EPSON AcuLaser C9200N Revision D
Troubleshooting      Image quality problem 147
Confidential
<4-COLOR> 
WHITE LINES IN MAIN SCAN DIRECTION, WHITE BANDS IN MAIN 
SCAN DIRECTION, COLORED LINES IN MAIN SCAN DIRECTION, AND 
COLORED BANDS IN MAIN SCAN DIRECTION
A. Typical Faulty Images
B. Troubleshooting Procedure
Step Section Check Item Result Action
1 Transfer Belt 
Unit
Fingerprints, oil, or other 
foreign matter is evident on 
the Transfer Belt.
YES Clean with specified solvent 
(Refer to Chapter 6 " 
MAINTENANCE (p. 331)")
2 Transfer Belt is dirty or 
scratched.
YES Clean dirty belt with a soft 
cloth. 
Change Transfer Belt if belt is 
damaged.
3 Cleaning Blade is not 
effective in removing toner 
completely.
YES Clean Cleaning Blade.
Change Transfer Belt Unit. 
(p.162)
4 2nd Transfer 
Roller
2nd Transfer Roller is dirty or 
scratched.
YES Change 2nd Transfer Roller. 
(p.169)
5 Paper path There is foreign matter on 
paper path.
YES Remove foreign matter.
6 Image Transfer Paper 
Separator Fingers are 
damaged or dirty.
YES Clean or change.
4036fs4025c0
4036fs4026c0
7 Fusing Unit Fusing Entrance Guide Plate 
is dirty or damaged.
YES Clean.
Change Fusing Unit. (p.162)
8 Fusing Paper Separator 
Fingers are dirty.
YES Clean.
9 Neutralizing 
Brush
The resistance values between 
the Neutralizing brush and the 
ground terminal is not 
∞.
NO Check the contact. Modify. 
Change Neutralizing brush.
10 The problem has been 
eliminated through the checks 
of steps up to 9.
NO Change Controller Board. 
(p.198)
Step Section Check Item Result Action