EPSON AcuLaser C9200N Revision D
ADJUSTMENT Adjustment Item 314
Confidential
5.1 Adjustment Item
The table below shows the adjustment item (including life counter clear) required when the specified part/unit is fixed or replaced.
Part/Unit Timing Item Adjustment Procedure Required Jig & Tool Reference
PH unit When assembling (Whether the
parts are new or old)
Skew Adjustment Adjust the gradient of the PH unit following
the values printed on the maintenance status
sheet.
None
Page 318
MP Tray Paper Guide Mechanism When assembling MP Tray Paper
Guide Mechanism
Mechanical Adjustment Position the specified part when assembling. None
Page 318
Main Board After replaced with a new one Writing of USB-ID Execute the item using the dedicated
program.
EPSON Page Printer Main
Board Initialization Tool
Page 318
Maintenance unit After replaced with a new one Reset Life Counter Execute using the Maintenance Menu. None Page 318
Feed roller (C2) After replaced with a new one Reset Life Counter Execute using the Maintenance Menu. None Page 318
Feed roller (C3) After replaced with a new one Reset Life Counter Execute using the Maintenance Menu. None Page 318
Feed roller (C4) After replaced with a new one Reset Life Counter Execute using the Maintenance Menu. None Page 318
---
If needed Controller Firmware Update Refer to the explaining page Page 318
---
If needed Engine Controller Firmware
Update
Refer to the explaining page
Page 318