5.2.2 MP Tray Mechanical Adjustment
PURPOSE
Adjust the mounting location of the MP tray to operate the MP tray properly.
PROCEDURE
1. Install the gear so that the protrusion of the gear [1] and the mark [3] on the rack
gear [2] are aligned in a straight line.
2. Place the MP tray to match the on the surface of the MP tray Unit with the
center of the scale.
3. After installing the base plate, check whether Paper Guide operates smoothly.
Figure 5-3. MP Tray Mechanical Adjustment
(%& #