EPSON AcuLaser C9200N Revision D
Troubleshooting      Image quality problem 145
Confidential
<MONOCOLOR> 
UNEVEN IMAGE
A. Typical Faulty Images
B. Troubleshooting Procedure
Step Section Check Item Result Action
1 Toner Cartridge The Toner Cartridge of every 
color is surely installed.
NO Re-install it.
2 PH Unit PH Unit is surely installed. NO Re-install it.
3 Uneven pitch occurs in 3.0 
mm pitch.
YES Replace PH Unit Stopper. 
(p.175)
4 Toner Cartridge There is any stain or breakage 
on the Drive section of the 
Toner Cartridge.
YES Clean/replace the Toner 
Cartridge.
5 Photoconductor 
Unit
There is any stain, damage or 
abrasion on the PC drum.
YES Change Photoconductor Unit. 
(p.162)
6 2nd Transfer 
Roller
There is any stain, damage, 
deformation or abrasion on the 
Transfer roller.
YES Replace the 2nd Transfer 
Roller. (p.169)
7 Fusing Unit There is any stain, damage, 
deformation or abrasion on the 
Roller and Drive section of the 
Fusing Unit.
YES Replace the Fusing unit. 
(p.162)
8 The problem has been 
eliminated through the check 
of step 7.
NO Change Transfer Belt Unit. 
(p.162)
4138fs4507c0