EPSON AcuLaser C9200N Revision D
Troubleshooting Power supply trouble 135
Confidential
3.4.3 Fusing Heaters do not operate 3.4.4 Power is not supplied to option
Optional Paper Cabinet Unit
Duplex Unit
Relevant Electrical Parts
Primary Interlock Switch (S2)
Fusing Unit
DC Power Supply (PU1)
Step Check Item
Location
(electrical
parts)
Result Action
1
Is the power source voltage applied
across CN2PU1-1 to 2 on PU1?
During this time, the Right Door
should be closed.
S to T-2 NO
Check wiring from
power outlet to S1 to
CN1PU1.
2
Is the power source voltage applied
across CN30-1 and 3, or across 2
and 3?
U-6
YES Fusing Unit
NO Change PU1. (p.193)
Step Check Item
Location
(electrical
parts)
Result Action
1
Is DC24 V being applied to hookup
connector CN44-2?
O-21 NO
Malfunction in Feeder
Unit
2
Is DC24 V being output from
CNCST-2 on PWB-M?
I-21 NO
Check wiring from
PWB-M to CN44 to
Feeder Unit.
3
Is DC24 V being output from
CN5PU1-2 on PU1?
---
YES Change PU1. (p.193)
NO
Malfunction in Feeder
Unit
Step Check Item
Location
(electrical
parts)
Result Action
1
Is DC24 V being output from
CN19-2 on Duplex?
O-19 NO
Malfunction in Duplex
Unit
2
Is DC24 V being output from
CNCOP-2 on PWB-M?
I-19 NO
Check wiring from
PWB-M to CN19 to
Duplex Unit.
3
Is DC24 V being output from
CNCOP-3 on PWB-M?
---
YES Change PU1. (p.193)
NO
Malfunction in Duplex
Unit