EPSON AcuLaser C9200N Revision D
Troubleshooting      Power supply trouble 135
Confidential
3.4.3  Fusing Heaters do not operate 3.4.4  Power is not supplied to option
 Optional Paper Cabinet Unit
 Duplex Unit
Relevant Electrical Parts
 Primary Interlock Switch (S2)
 Fusing Unit
 DC Power Supply (PU1)
Step Check Item
Location
(electrical 
parts)
Result Action
1
Is the power source voltage applied 
across CN2PU1-1 to 2 on PU1?
During this time, the Right Door 
should be closed.
S to T-2 NO
Check wiring from 
power outlet to S1 to 
CN1PU1.
2
Is the power source voltage applied 
across CN30-1 and 3, or across 2 
and 3?
U-6
YES Fusing Unit
NO Change PU1. (p.193)
Step Check Item
Location
(electrical 
parts)
Result Action
1
Is DC24 V being applied to hookup 
connector CN44-2?
O-21 NO
Malfunction in Feeder 
Unit
2
Is DC24 V being output from 
CNCST-2 on PWB-M?
I-21 NO
Check wiring from 
PWB-M to CN44 to 
Feeder Unit.
3
Is DC24 V being output from 
CN5PU1-2 on PU1?
---
YES Change PU1. (p.193)
NO
Malfunction in Feeder 
Unit
Step Check Item
Location
(electrical 
parts)
Result Action
1
Is DC24 V being output from 
CN19-2 on Duplex?
O-19 NO
Malfunction in Duplex 
Unit
2
Is DC24 V being output from 
CNCOP-2 on PWB-M?
I-19 NO
Check wiring from 
PWB-M to CN19 to 
Duplex Unit.
3
Is DC24 V being output from 
CNCOP-3 on PWB-M?
---
YES Change PU1. (p.193)
NO
Malfunction in Duplex 
Unit