EPSON AcuLaser C9200N Revision D
Troubleshooting      Overview 98
Confidential
3.1.3  Precautions in Performing Troubleshooting Work
1. Be sure to unplug the POWER CORD before starting troubleshooting work unless 
instructed to plug it.
2. In case of performing work with covers removed, the interlock and the safety 
switches turned ON, and the power turned ON, disconnect the connector on the 
PH Unit if not necessary.
3. In case of performing work with covers removed, the interlock and the safety 
switches turned ON, and the power turned ON, be careful of a high voltage 
supplied from the high-voltage power supply.
4. When touching any hot surfaces, take care not to burn yourself.
5. Wear a wrist strap to discharge static electricity from body of worker.
3.1.4  Troubleshooting Flowchart
Never touch any live parts unnecessarily when the power is 
on. Never touch the power switch/inlet part even after the 
power switch is turned OFF as the part is alive unless the 
power cord is unplugged.
In case of performing work with covers removed, the 
interlock and the safety switches turned ON, and the power 
turned ON, a laser beam may be emitted from the PH Unit.
In case of performing work with covers removed, the 
interlock and the safety switches turned ON, and the power 
turned ON, never touch the high-voltage power supply and 
any other high voltage output part as a high voltage may be 
output from high voltage unit.
Fix the trouble with reference to the 3.4 
Power supply trouble (p. 134).
Yes
Yes
Yes
Yes
No
No
No
No
Fix the trouble with reference to the 
3.2 Jam Display (p. 99).
Fix the trouble with reference to the 3.3 
Service Call Error (p. 107).
Fix the trouble with reference to the 3.5 
Image quality problem (p. 136).
Is it a power supply trouble?
Is it an image quality 
problem?
Is an error message (error code) displayed on the 
control panel?
Is it a jam error code?
Fix the trouble with reference to the Ch2 " OPERATING PRINCIPLES (p. 31)" 
and Ch7 " APPENDIX (p. 337)".
Start