EPSON Perfection V10/V100 Photo/V200 Photo/V350 Photo Revision B
PRODUCT DESCRIPTION Basic Specifications 10
TPU (Perfection V100 Photo / V200 Photo)
ELECTRICAL SPECIFICATIONS
Main Unit
• Rated voltage 13.5 VDC
• Input voltage range 13.5 to 14.85 VDC
• Power consumption
• Rated current 1.5 A
AC Adapter
• Rated voltage 100-120 VAC (100 V)
220-240 VAC (200 V)
• Input voltage range 100-120 VAC ± 10%
220-240 VAC ± 10%
• Rated current 0.6 A (at 100 VAC)
0.4 A (at 220 VAC)
• Rated frequency 50 to 60 Hz (100 V, 200 V models)
• Input frequency 50 to 60 Hz ± 0.5 Hz (100 V, 200 V models)
• Rated output voltage 13.5 VDC
• Output voltage range 13.5 to 14.85 VDC
• Rated output current 1.5 A
• Current resistance 100 M
Ω or more at 500VDC
( AC input terminal and DC output terminal)
• Voltage resistance 3000 VAC for 1 min.
(AC input terminal and DC output terminal)
• Leakage current less than 0.25 mA
• Inrush current Max. 60 A (100 V, 200 V models)
• Static electricity Contact discharge: 2kV, 4kV, 5kV
Air discharge: 2kV, 4kV, 8kV, 10kV
ENERGY CONSERVATION
Environmental Protection International Energy Star Program compliant
Korea Energy Star
Ecoleaf (Perfection V350 Photo)
ENVIRONMENTAL OPERATING CONDITIONS
• Dust Ordinary office or home condition
(Extreme dust should be avoided)
• Luminous intensity Avoid direct sunlight and vicinity of light
source
Product type Lid-type scanning unit for transparent documents
Light Source White cold cathode fluorescent lamp
Max scan size
33.0 mm x 244.3 mm
Document
Strip film: 35 mm x 6 frames
Slide film: 35 mm x 4 frames
Document setting
method
Use a film holder
(Strip/slide film integral type)
Power supply Supplied from the scanner (main unit)
Condition
Perfection
V10
Perfection
V100 Photo
Perfection
V200 Photo
Perfection
V350 Photo
Operation 16W 16.5W 20W
Standby Mode 12W 13W 14.0W 13.5W
Sleep Mode 3.5W 3.6W 4.1W
Table 1-2. Environmental Conditions
Condition Temperature
Humidity
(non-condensing)
Operating 5 to 35 °C 10 to 80%
Storage -25 to 60 °C 10 to 85%