Epson Stylus Pro 7700/7710/7700M/7710M/7900/7910/9700/9710/9900/9910/WT7900/WT7910/9890/9908/7890/7908 Revision I
DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 346
Confidential
4.4.8.17 Paper Pressing Motor
1. Remove the Color Measurement Device. (p325)
2. Remove the Mounter. (p327)
3. Remove the Paper Pressing Encoder. (p340)
4. Remove the screw that secures the Carriage Motor mounting plate, and remove the
Carriage Motor Mounting Plate.
A) Silver, Phillips, Bind machine screw M4x8: one piece
5. Disconnect the relay connector of the Paper Pressing Motor.
6. Release the harness from the clamp.
7. Remove the two screws that secure the Paper Pressing Motor, and remove the
Paper Pressing Motor.
B) Silver, Phillips, Bind machine screw M3x4: two pieces
Figure 4-224. Removing the Carriage Motor mounting plate
Figure 4-225. Removing the Paper Pressing motor
C A U T I O N
In the next steps, take care not to damage the scale of the Paper
Pressing Encoder.
A D J U S T M E N T
R E Q U I R E D
Be sure to refer to Chapter 5 “Adjustment” (see p351) and perform
specified adjustments after replacing the Paper Pressing Motor.
<Adjustment Item>
1. Counter Clear (Paper Pressing Motor)
A
Carriage Motor mounting plate
B
Clamp
Relay connector
Paper Pressing Motor