Crically low supply voltage.
(<185V)
Check supply voltage.
E3.1
TCO 1 (Heat exchanger) has
gone over temperature.
Check that fans are plugged in, cleaned, and free turning - room air fans may be
slowed or stalled.
Check the burner pressure -being set too high may result in excess heat build-
up.
Check the gas jets are correct.
E3.2
TCO 2 (Lower chassis) has
gone over temperature.
Check that fans are plugged in, cleaned, and free turning.
Check fan capacitors are plugged in - secondary room air fan may be slowed or
stalled.
E3.3
TCO over current protecon
acvated.
Check that TCO wiring terminals are properly connected and not touching the
chassis or rebox.
E4.1
Primary valve solenoid
current abnormal.
Check that the connecons to each solenoid are secure and in place.
The primary solenoid on the valve inside the re may have failed. If this is the
case, the coil will need to be replaced.
E4.2
Secondary valve solenoid
drawing current when
supposed to be o.
Contact Escea technical support.
E4.3
Secondary valve solenoid
overcurrent protecon
acvated.
The valve solenoids have failed the pre-ignion test. A wire may have dislodged
or the valve solenoid is faulty.
Check that the connecons to each solenoid are secure and in place.
The connecons on the ends of the wires may need to be ghtened (e.g. with a
pair of pliers) to ensure a robust connecon to the valve terminal.
Check the wiring to the soleniods for damage.
E4.4
Secondary valve solenoid
drawing too much current.
E4.5
Secondary valve solenoid
drawing too lile current.