IP Server 900 Programming Manual Function 1: System function programming
D.5
Function 155: SIP station timers
Function 1551: SIP station registration timer
Because the system cannot detect when a SIP station becomes disconnected, the system requires that
the station periodically re-register. This function determines the amount of time a SIP station registration
will last. If this timer expires before a new register request is received the system will consider the phone to
be disconnected. The value is in seconds.
Range: 5–3600. Default: 1800.
Function 156: Cell phone delay
When one uses a cellular phone or cordless phone to pick up messages, this usually requires the user to
move the phone away from the ear frequently in order to press command keys, making the user miss some
portion of the next prompt. This function adds additional delay before the playback of system prompts during
remote message pickup or message pickup from an analog station (this does not affect ESI phone message
pickup). The value is in seconds.
Range: 0.0–5.0. Default: 1.0.
Function 157: Device timers
Field 1: Door unlock relay timer
Used only with ESI Presence Management. This is the number of seconds that a door-unlock relay will
remain open after one has pressed a remote door-unlock key.
Range: 2–60 seconds. Default: 4.
Field 2: Fax server dial delay
This is the amount of time the system will pause before sending the DID digits to a fax server after the call
has been answered.
Range: 5–100. Default: 50 (500 ms).
Function 158: VIP 7 PC Attendant exit timer
This is the amount of time it takes an Attend department call (see “Department hunting methods,” page F.28)
to enter and exit the Attendant queue.
Range: 5–900 seconds. Default: 180.
Function 16: System feature parameters
Function 161: Recording alert tone
This sets whether the system plays a short beep tone every 15 seconds during a call recording, indicating to
both parties that a recording is in progress.
Default: Disabled (the beep doesn’t play).
Important: IN MOST JURISDICTIONS, IT IS PERMISSIBLE TO RECORD A CONVERSATION IF ONE OF THE
TWO PARTIES IS AWARE THAT IT IS BEING RECORDED. HOWEVER, ESI TAKES NO
RESPONSIBILITY AS TO ITS LEGALITY IN ALL JURISDICTIONS. IT IS THE RESPONSIBILITY OF
THE INSTALLING COMPANY AND THE END USER TO DETERMINE AND FOLLOW THE
APPLICABLE STATE AND LOCAL LAWS REGARDING RECORDING OF CONVERSATIONS.
Function 162: Connect tone
This sets whether the system plays a system connect tone (two short beeps a user hears when a
station answers).