ES415.1 - User’s Guide72
Technical Data ETAS
DIN EN 60068-2-14 Nb Temperature change:
Temperature: Tu –40 °C / To +120 °C,
Number of cycles: 10,
Unit under test: active
DIN EN 60068-2-56 Humidity storage
DIN EN 60068-30, Variant 1 Climate change
DIN EN 60068-2-64,
ISO 16750-3
Vibration, noise:
3 space axis, test duration 4 h,
Unit under test: active
In addition, the combination was tested
by cascaded modules.
ISO 16750-3, Sec. 4.2.2.2 Mech. shock
3 space axis, half sinus,
Acceleration: 500 m/s²,
Shock duration: 6 ms,
Shocks per direction and axis: 10,
Units under test: active
ISO 16750-3, Sec. 4.3 Drop test
Number of drops: 2,
Height: 1 m,
Surface: concrete, steel
Units under test: passive
ISO 16750-4, Sec. 5.2 Phased temperature test
ISO 16750-4, Sec. 5.4.2 Splash water
Air temperature: To +120 °C,
Cycle duration: 30 min,
Splash length: 3 s,
Splash quantity: ca. 3 l,
Splash water temperatur: +2 °C ± 2 °C,
Medium: water, put in 3% Arizona dust
fine,
Number of cycles: 100,
Unit under test: active
ISO 16750-4, Sec. 5.5.1.;
DIN EN 60068-2-52
Salt fog:
Severity level: 5,
Test duration: 16 d,
Units under test: passive
ISO 16750-5 Chemical resistance:
Identification A-W,
Prüflinge passiv
DIN 5596-1 Stone impact
IPX7 Protection class test:
Protection class IP67
Norm Test