ES415.1 - User’s Guide 77
ETAS Technical Data
7.8 Electrical Data
This chapter contains information on the following topics:
"Host Interface ("IN" Connection)" on page 77
"Power Supply" on page 78
"Sensor Power Supply" on page 78
"Sensor Inputs" on page 79
"Signal Processing" on page 81
7.8.1 Host Interface ("IN" Connection)
Note
ETAS guarantees measurement accuracy of the ES415.1 for one year. Please
use our calibration service (see section 4.9 on page 33)!
Note
Unless otherwise specified, all data applies at 25 °C.
Connection 100Base-T Ethernet; 100 Mbit/s,
Full Duplex
Protocol XCP on UDP/IP
IP address Dynamic via INCA or via
ES4xx Configuration Tool
(default setting: 192.168.40.44)
Note
For the successful initialization of the network card of your PC, observe chapter
7.7.1 on page 75.

Table of Contents