04-2017 5325 00 13
soliDs
The appliance displays the solid residue full
warning when the number of programmed
dispenses has been reached.

and the “Solid residue full” message is dis-
played.
The appliance will still be able to dispense
instant drinks.
To remove the solid residue container, pro-
ceed as follows:
1. Open the door of the appliance.
2. Grasp the sides of the liquid residue con-
tainer, lift it slightly and pull outwards.
3. Remove the solid residue container,
empty it and wash it with a neutral deter-
gent solution.
4. Reset the fault warning from the “daily
actions” function.
5. Reposition the containers.
1
2
3
4
5
6
Fig. 11
1. Liquid residue container
2. Liquid residue container lid fastening hooks
3. Liquid residue container lid
4. Solid residue container*
5. Microswitch for the residue full float valve
6. Liquid residue container full float valve
* Not fitted on instant models.
CLEANING THE BREWING UNIT
After each load or at least once a week, it
is good practice to clean the external parts
of the brewing unit by removing any pow-


CLEANING THE WATER SUPPLY
TANK
For models with a water supply tank only.

being used, the internally-supplied water
tank must be emptied of any residual water
and sanitised, whilst making sure to me-
chanically remove any residues and visible

SWITCHING THE MACHINE ON
Every time you switch on the appliance, it
performs initial checks by dispensing hot
water from the nozzles.
The screen which shows the heating-up
status of the heating unit is displayed.
The selections are not available until the
heating unit has reached its operating tem-
perature.