44
9-2-2. Procedure of Replacing Hydraulic Oil
a. Firstly dismantle the right side protection cover as following drawing
Table (1) Table (2)
1. Firstly prepare a proper waste oil tank, reference as table (2)
2. Release the stopper with proper wrench
1
, before removing the stopper, put a container below to avoid
leaking of oil
2
3. Remove stopper
1
, let the waste oil pour into oil tank
2
, place the stopper at a clean place
4. After the pouring, restore the stopper tightly
5. Transfer the waste oil into a big oil container to prevent pollution
ITEM
NAME
1
Stopper
2
Waste oil tank
Model
KP-200
Waste oil tank
1.8L
ITEM
NAME
1
Waste oil tank
2
funnel
3
Waste oil container
Right Side
Protection Cover