Test Setup - Test Configurator, Timer, and System
128 FTB-700G/800 Series
Clock
Ext Clock Out
Note: Available when the Clock Mode is set to Internal, or Recovered.
Allows to set the clock that will be generated.
Interface Type allows the selection of the clock interface:
DS1 (default), E1, and 2MHz.
Ext Clock Out on a green background indicates that a valid clock is
generated on the EXT CLK port.
LOC on a red background indicates that no clock is generated on the
EXT CLK port.
LBO (Line Build Out), available with DS1 only, allows the selection of
the interface Line Build Out that meets the interface requirements over
the full range of cable lengths: DSX-1 (0-133 ft) (default),
DSX-1 (133-266 ft), DSX-1 (266-399 ft), DSX-1 (399-533 ft), and
DSX-1 (533-655 ft).
Line Coding, available with DS1 and E1, allows the selection of the
interface line coding.
For DS1: AMI and B8ZS (default).
For E1: AMI and HDB3 (default).
Framing, available with DS1 and E1, allows the selection of the
interface framing.
For DS1: SF, SLC-96, and ESF (default).
For E1: PCM30 (default), PCM30 CRC-4, PCM31, and PCM31 CRC-4.