Test Setup - Test Configurator, Timer, and System
NetBlazer 117
BERT
BERT
From the Test menu, tap Setup, Test Configurator, and tap on the BERT
block.
Pattern
The icon next to the Pattern label indicates the status of the received
pattern signal. Refer to Status Bar on page 28 for more information.
Coupled RX to TX check box, when selected (default), allows
coupling both the TX and RX signal with the same test pattern.
For a framed test, the Coupled RX to TX check box is selected and
cannot be cleared.
No Pattern Analysis (Live) check box when cleared (default),
monitors the received traffic pattern. For live traffic, the No Pattern
Analysis (Live) check box should be selected as the traffic is a live
pattern thus there is no analysis of pattern loss, bit error, and no traffic
indications. Only available with a framed test.