Test Setup - Test Configurator, Timer, and System
170 FTB-700G/800 Series
Link OAM
Link OAM
From the test menu, tap Setup, Test Configurator, and the
Link-OAM (802.3) test block.
OAM Mode
Allows the selection of the OAM mode:
Active (default) initiates the OAM discovery and send OAMPDU
loopback control; doesn’t respond to variable request nor generate
Link Event Notification.
Passive doesn’t initiate OAM discovery nor send OAMPDU loopback
control.
OAMPDU Destination MAC Address
Indicates and allows to change the default multicast OAM PDU destination
MAC address: 01:80:C2:00:00:02.
Default check box when cleared (default is selected), allows the
configuration of the OAM PDU destination MAC address:
00:00:00:00:00:00 to FF:FF:FF:FF:FF:FF.
Pass/Fail Verdict
Pass/Fail Verdict check box when selected (default) enables the use of the
pass/fail verdict. A global fail verdict is declared when any of the following
condition is met: Link Down, any Link OAM alarm, Remote Alarms (if
enabled), or Remote Loopback (if enabled).
Remote Alarms check box when selected (default) considers the
following alarms to declare the pass/fail verdict: Critical Event, Dying
Gasp, and Link Fault.
Remote Loopback check box when selected (default) considers
successful/unsuccessful remote loopback request to declare the
pass/fail verdict.