EasyManua.ls Logo

EXFO FTB-860 - RFC 2544 - Global

EXFO FTB-860
675 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Test Setup - Test Configurator, Timer, and System
206 FTB-700G/800 Series
RFC 2544 - Global
RFC 2544 - Global
From the Test menu, tap Setup, Test Configurator, tap on the RFC 2544
block, and on the Global tab.
Dual Test Set
Dual Test Set (DTS) check box when selected (cleared by default)
enables RFC 2544 Dual Test Set. Once Dual Test Set is enabled, use
the Discover Remote button to select a remote unit.
Note: Alternatively it is possible to use the Discover Remote button to connect to a
remote module and automatically enable the Dual Test Set. For more
details, refer to Discover Remote Button on page 530.
Disconnected indicates that there is no connection established with a
remote module.
Connected indicates that the connection is established with a remote
module.
Discover Remote button allows to discover remote modules
supporting Remote Loopback and/or Dual Test Set. For more details,
refer to Discover Remote Button on page 530.
Global Options
Flow Direction allows the selection of the traffic direction as follows:
TX to RX for Single Port topology.
Local to Remote, Remote to Local, and Bidirectional for Dual
Test Set.
Rate Unit determines the unit used to display the rate values: %,
Mbit/s, or Gbit/s.
Pass/Fail Verdict check box when selected (default) enables the use
of the pass/fail verdict.

Table of Contents

Related product manuals