Physical Interfaces and LEDs
24 FTB-700G/800 Series
ETHERNET 10/100/1000M
ETHERNET 10/100/1000M
This port can be used for electrical Intelligent Apps, Ethernet, or
Packet Sync test applications.
Supported electrical rates are 10Mbits/s, 100Mbit/s, and 1000Mbit/s.
10Mbits/s is not supported for SyncE. Plug the 10/100/1000 electrical
interface or the cable to be tested to the ETHERNET 10/100/1000M (PORT
#1 or PORT #2) connector. The electrical ports is RJ45 for category 5
unshielded twisted pair (UTP). Refer to Ethernet Cables on page 606 for
cable specifications.
2M-155M (PORT #1)
This port can be used for electrical Transport test applications.
Supported electrical signal are E1/2M, E3/34M, DS3/45M,
STS-1e/STM-0e/52M, E4/140M, and STS-3e/STM-1e/155M. Plug the signal to
be tested to the BNC IN and OUT ports. Connector type is BNC for coaxial
75-ohm cable connection.
2M-52M (PORT #2)
This port can be used for electrical DS3 dual RX Transport test application.
Supported electrical signal are DS1 or DS3 for Dual RX testing capability.
Plug the signal to be tested to the BNC IN port. Connector type is BNC for
coaxial 75-ohm cable connection.
1.5M/2M (PORT #1/#2)
This port can be used for electrical Transport test applications.
Supported electrical signal are DS1/1.5M and E1/2M. Plug the signal to be
tested to either Bantam or RJ48C port.