Test Setup - Test Configurator, Timer, and System
210 FTB-700G/800 Series
RFC 2544 - Subtests
Trial Duration is the time for each trial in minutes:seconds: 1 second
(default) to 30 minutes.
Accuracy is the accuracy measurement in percentage of the line rate
(%), Mbit/s, or in Gbit/s. The accuracy is not based on the configured
Maximum Rate but on the Ethernet line rate. The accepted values are
as follows:
Validations represents the number of times the result should be
validated: 1 (default) to 50 times.
Interface
Speed
Max. Rate
% Mbit/s Gbit/s
10 Mbit/s 0.1 to 10.0
(default 1.0)
0.01 to 1.0
(default 0.10)
Not Applicable
100 Mbit/s 0.1 to 10.0
(default 1.0)
0.1 to 10.0
(default 1.0)
Not Applicable
1000 Mbit/s 0.1 to 10.0
(default 1.0)
1 to 100.0
(default 10)
0.001 to 0.100
(default 0.010)
10G LAN 0.1 to 10.0
(default 1.0)
10.0 to 1000.0
(default 100)
0.01 to 1.00
(default 0.10)
10G WAN 0.1 to 10.0
(default 1.0)
10.0 to 1000.0
(default 100.00)
0.01 to 1.00
(default 0.1)