EasyManua.ls Logo

EXFO FTB-860 - Page 271

EXFO FTB-860
675 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Test Setup - Test Configurator, Timer, and System
NetBlazer 259
Signal - Signal Configuration (SONET/SDH)
REI-L/MS-REI Computation Method (OC-192/STM-64 only): Allows to
select the default method used to calculate the REI-L/MS-REI error for
OC-192 and STM-64 signals. Choices are M1 Only and both M0 and M1.
The default setting is M1 only.
STS/AU and VT/TU Mappings
Timeslot/Number
Timeslot (SONET) allows the selection of the STS timeslot number.
Refer to SONET Numbering Convention on page 630 for more
information.
Number (SDH) allows the selection of the AU channel number. Refer
to SDH Numbering Convention on page 631 for more information.
TCM check box when selected (cleared by default) allows Tandem
Connection Monitoring (TCM).
TC-UNEQ-P / TC-UNEQ-V / HPTC-UNEQ / LPTC-UNEQ check boxes
when selected (cleared by default) allows the monitoring of the
corresponding Tandem Connection - Unequipped alarm. Only
available when the TCM check box is selected.
Overwrite Fixed Stuff (STS-1 only) check box when selected (default)
fills up the bytes of the STS-1 SPE’s columns 30 and 59 with the
selected pattern from the tab BERT on page 117.
Background Traffic allows the selection of the high order path
background traffic: AIS, Equipped (PRBS23) - (default), or
Unequipped.

Table of Contents