Test Results
324 FTB-700G/800 Series
Alarms/Errors
PTP
Alarms
Loss Sync
RX: The Slave Clock does not receive packet timing signal messages
(Sync, Follow Up, Delay Resp) within their expected arrival time for a
duration exceeding the configured Receipt Timeout (refer to PTSF
Alarm Timeout/Threshold on page 115).
Loss Announce
RX: The Slave Clock does not receive Announce messages within their
expected arrival time for a duration exceeding the configured Receipt
Timeout (refer to PTSF Alarm Timeout/Threshold on page 115).
Unusable
RX: Either the maximum Sync IPDV value or the maximum Delay Req
IPDV value in the last second exceeds the configured IPDV Threshold
(refer to PTSF Alarm Timeout/Threshold on page 115).
QL Mismatch
RX: The received QL value does not match the Expected QL (refer to
page 115 or page 374). The QL Mismatch alarm is only reported when
at least one Announce message has already been received (Last QL
Received) and that the QL Mismatch Monitoring check box is
selected.

Table of Contents