Test Results
NetBlazer 393
Summary
Bit/Pattern Error Rate/Count graphically displays a meter
representing either the bit/pattern error rate or the bit/pattern error
count depending on the Pass/Fail Verdict selection
1
.
When the verdict is enabled
1
, the values under the threshold are
presented in green while the values above are in red.
When the verdict is disabled, the bit/pattern error rate is displayed in
blue.
The arrow pointer indicates the current received bit/pattern error
rate/count.
The Pass/Fail verdict is displayed just on top of the meter when
enabled
1
.
Bit/Pattern Error, Amount/Rate, and Inject: The bit/pattern error
injection and settings are coupled with the Inject Button on page 346.
For Transport test applications, not available in Through modes or with
Multi-Pattern.