Test Control
NetBlazer 553
Save/Load Button
The load function opens and applies the test configuration from a
previously saved configuration file.
To load a configuration:
1. Select the media from where the file will be loaded; Favorites,
Factory Defined, Others, or a removable drive (USB key for example)
if present.
Favorites lists configuration files from:
Documents\810-880-NetBlazer\Configuration\Favorites.
Factory Defined lists the factory configuration files.
Others lists configuration files from:
Documents\810-880-NetBlazer\Configuration.
2. Select the file from the list.
3. Select or clear the Overwrite report settings check box as required.
The Overwrite report settings check box when selected (default)
replaces the current report settings by those from the configuration
that is loaded.
4. Tap the Load button.
Note: Configuration file has a limited backward compatibility (Typically the
backward compatibility period is one year or three software releases).