Standards and Environmental Data
Table 142: Safety Standards
North American Safety of ITE UL 60950-1 2nd Ed., A2:2014 (US)
CSA 22.2 No. 60950-1-07 2nd Ed. 2014-10(Canada)
Complies with FCC 21CFR 1040.10 (US Laser Safety)
CDRH Letter of Approval (US FDA Approval)
European Safety of ITE IEC 60950-1:2005 2nd+A1:2009+A2:2013
IEC 60950-1:2006+A11+A1+A12+A2
EN 60825-1:2007 (Lasers Safety)
International Safety of ITE CB Report & Certificate per IEC 60950-1:2005 2nd Ed.,
+ National Dierences
AS/NZX 60950-1 (Australia /New Zealand)
Table 143: EMI/EMC Standards
North America EMC for ITE FCC CFR 47 part 15 Class A (USA)
ICES-003 Class A (Canada)
European EMC standards EN 55032: 2015, Class A
EN 55024:1998+A1:2001+A2:2003
Class A includes IEC 61000-4-2, 3, 4, 5, 6, 11
EN 61000-3-2: 2006+A2:2009 (Harmonics)
EN 61000-3-3:2008 (Flicker)
ETSI EN 300 386: v1.4.1 (2008-04) (EMC Telecommunications)
2014/35/EU Low Voltage Directive
International EMC certifications CISPR 32: 2015, Class A (International Emissions)
EN 55024:1998+A1:2001+A2:2003 Class A (International Immunity)
IEC/EN 61000-4-2:2008 Electrostatic Discharge, 8kV Contact, 15 kV Air,
Criteria A
IEC/EN 61000-4-3:2008 Radiated Immunity 10V/m, Criteria
IEC/EN 61000-4-4:2004 Transient Burst, 1 kV, Criteria A
IEC/EN 61000-4-5:2005 Surge, 2 kV L-L, 2 kV L-G, Level 3, Criteria A
IEC/EN 61000-4-6:2008 Conducted Immunity, 0.15-80 MHz,
10V/m unmod. RMS, Criteria A
IEC/EN 61000-4-11:2004 Power Dips & Interruptions, >30%,
25 periods, Criteria C
Country-specific VCCI Class A (Japan Emissions)
BSMI (Taiwan Emissions)
ACMA (C-Tick) (Australia Emissions)
CCC Mark (China)
KCC Mark, EMC Approval (Korea)
Table 144: Telecom Standards
EN/ETSI 300 386:2008 (EMC Telecommunications)
EN/ETSI 300 019 (Environmental for Telecommunications)
MEF9 and MEF14 certified for EPL, EVPL, and ELAN