Digital Brushless AC servo drive system - Ref.0707 MCS- 67/92
Units: The units of the variable being displayed.
Valid values: 0, ..., 9999.
Default value: 4000 and 3000 respectively.
Example: If OP1= 04 [SV2] (VelocityFeedback, in rev/min) and OP3 =
3000.
It means that when the value of SV2 is 3000 rev/min the
analog output will be 10 V and it maintains this (rev/min)/V
ratio throughout its full range ±10V.
Function: Sets the polarity (inverted or not inverted) of the program-
mable digital input (pins 1 and 2 of X2).
Valid values:
0. Not inverted (by default)
1. Inverted
Function: They determine the activation of the various outputs of the
digital functions available.
OP6 USER, RW DigitalOutputPolarity
OP14 USER, RW DigitalOutputFunctionSelector
OP14 Function
00 Not used
 OV10 as
output from
function Nr
01 OutFunc1
02 OutFunc2
03 OutFunc3
04 OutFunc4
05 OutFunc5
06 OutFunc6
07 OutFunc7
X2.1
OP6
OV10
0
1
X2.2