EasyManua.ls Logo

FCI MT100 - Page 76

FCI MT100
160 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATION MT100 Multipoint Flow Meter
Command 188: Read KFactor4
Byte
Format
Description
Request Data Bytes
0–3
Float
Read KFactor4
Response Data Bytes
0–3
Float
Read KFactor4
Code
Class
Description
Response Codes
0
Success
No Command-Specific Errors
1–127
Undefined
Command 191: Totalizer Reset
Byte
Format
Description
Request Data Bytes
0
Unsigned-8
Reset Key = 0x00
Response Data Bytes
0
Unsigned-8
Reset Key = 0x00
Code
Class
Description
Response Codes
0
Success
No Command-Specific Errors
1
Undefined
2
Data Entry Error
Invalid Selection
3–4
Undefined
5
Data Entry Error
Too Few Data Bytes Received
6
Undefined
7
Mode Error
In Write Protect Mode
8–15
Undefined
16
Mode Error
Access Restricted
17127
Undefined
Command 193: Read Process Variable and Time Stamp
Byte
Format
Description
Request Data Bytes
0–13
Float
Read PV and Timestamp
Response Data Bytes
0–13
Float
Read PV and Timestamp
Code
Class
Description
Response Codes
0
Success
No Command-Specific Errors
1–127
Undefined
Command 195: Read Flow Element (FE) Faults
Byte
Format
Description
Request Data Bytes
0–31
Enum
Read FE Faults
Response Data Bytes
0–31
Enum
Read FE Faults
Code
Class
Description
Response Codes
0
Success
No Command-Specific Errors
1–127
Undefined
Fluid Components International LLC 68

Table of Contents

Related product manuals