TROUBLESHOOTING MT100 Multipoint Flow Meter
Figure 52 NAMUR Output Level Selection
When NAMUR is enabled, and a fatal fault is detected, the 4-20 mA output is forced to the preselected NAMUR output level. Use the Click
to Test NAMUR button (forces NAMUR output) as needed to verify the system setup and wiring.
Table 23 Fatal Faults that Trigger NAMUR
Fault Bit
Fatal Fault Error Or Status Descriptions
1
CORE: any of these errors: I2C error, UART error, Mutex error or Watchdog Reset.
4
CORE: unable to update process data (PD_NO_FE_DATA). Unable to obtain/use data from any active FEs.
6
CORE: detects FRAM/SPI error.
11
(Any) FE Board Temperature Out of Limits
14
CORE: unable to communicate with one or more FEs (PD_COMM_ERROR).
20
CORE: averaged temperature above “Temperature Max.”
21
CORE: averaged temperature above “Temperature Min.”
22
(Any) FE reports SENSOR_HEATER_SHORTED_FAULT.
24
(Any) FE reports SENSOR_HEATER_OPEN_FAULT.
27
(Any) FE reports SENSOR_ ADC_BELOW_ MIN_FAULT.
30
(Any) FE reports SENSOR_ ABOVE_ MAX_TEMPERATURE_FAULT.
31
(Any) FE reports SENSOR_ UNDER_ MIN_TEMPERATURE_FAULT.
32
(Any) FE reports TMP100_TEMPERATURE_ADC_FAULT.
33
(Any) FE reports LTC2654_DAC_FAULT.
36
(Any) FE reports I2C0_FAULT.
37
(Any) FE reports HEATER_MONITOR_ADC_FAULT.
38
(Any) FE reports PORT_EXPANDER_FAULT.
39
(Any) FE reports DELTA-R_ADC_FAULT.
40
(Any) FE reports REF-R_ADC_FAULT.
41
(Any) FE reports FE_FRAM_FAULT.
42
(Any) FE reports ACT_EXC_CURRENT_FAULT.
43
(Any) FE reports REF_EXC_CURRENT _FAULT.