206
FAULTS AND REMEDIAL ACTIONS
Fault-module
Fault-module
Fault-module
Fault-module
2. Engine oil pressure
Display accompanied by a continuous beep and warning light.
Switch off engine immediately.
Check the oil level.
Cause Remedial Action
Engine oil pressure too low as a result of
insufficient or excessively thin oil.
Top up engine oil or fill with correct oil.
Oil control valve in filter head dirty. Clean oil control valve (workshop task).
3. Charge air temperature
Display accompanied by a continuous beep and warning light.
Unload the engine immediately, then switch off.
Cause Remedial Action
Charge air dirty. Check charge air cooler, and clean if necessary.
Cracked V-belt. Replace V-belt.
Viscous fan faulty. Replace viscous fan (at workshop).
4. Hydraulic oil temperature
Display accompanied by a continuous beep and warning light.
Relieve the hydraulic system of load and switch off the engine.
Cause Remedial Action
When carrying out hydraulic operations, the con-
trol valve does not engage in 'Neutral'.
Set control valve to "Neutral" and lock / have fault
corrected at workshop.
Three-point implement is non-standard / lateral
support set too narrow.
Adapt three-point implement to standard /
change side support. If necessary make lifting
struts longer, if lifting height is sufficient.
Three-point implement too heavy / overpressure
valve continuously activated in upper limit
position of power lift.
Connect upper link to a different point on the
implement; measure pressure during the lifting
process (at workshop).
Insufficient oil suply for the operation concerned. Check and top up oil level.
Final shutoff incorrectly adjusted. Re-adjust final shutoff (at workshop).
5. Hydraulic oil level (early warning)
Display accompanied by a continuous beep and warning light.
Hydraulic tank could be empty.
Flow rate is limited to 10 l/min for all valves.