A Technical appendix
Festo – GDCP-CMMS-AS-G2-HW-EN – 1310NH – English 45
Operating and Environmental Conditions
Permissible setup altitude above sea level
with rated output [m] 1000
with power reduction:
10 % every 1000 m
[m] 1000 … 2000 (max.)
Relative air humidity [%] 0 … 90 (non-condensing)
Protection class IP20
Degree of c ontamination 2
Ambient temperature
with rated output [°C] 0…+40
with power reduction:
4%per[K]
[°C] +40 … +50
Storage temperature [°C] -25 … +70
Cooling Passive
Switch-off temperature, heat sink
Power section
[°C] ≥ 95
Vibration and shock resistance
Operation in accordance with EN 61800-5-1, section 5.2.6.4
Transport in accordance with EN 61800-2, section 4.3.3
Tab. A.2 Technical data: Operating and ambient conditions