DC100 MAX Digital Dispenser Operating Manual
© 2023 Fisnar - 65 - DC100 MAX Rev 4
Pin #6 Alarm Out (Output):
- The signal will be activated if any one of the below conditions occur.
o If the external “Alarm In” input circuit has been activated.
o If the “Glue Alarm” has been activated by reaching zero (0).
o If the “Pressure Alarm” has been activated due to the pressure being outside of the set
tolerance.
o If the “Vacuum Alarm” has been activated due to the vacuum being outside of the set
tolerance.
o If the “Dispense Count Limit” has reached the set limit value.
- A pop-up message will be displayed on the home screen of the machine confirming the reason why
the “Alarm Out” signal has been activated.
- If the “Alarm Out” signal is activated during a program cycle, the program cycle will be automatically
stopped.
- It will not be possible to actuate a new program cycle until the “Alarm Out” signal has been switched
off and the machine reset by pressing the button or momentarily (two (2) seconds) activating
pin #16 of the I/O input circuit.
Pin #10 Machine Busy (Output):
- When the machine is actuating a program cycle the signal will be activated.
- When the machine is in the function menu the signal will be activated.
Pin #12 End of Cycle (Output):
- When the machine has completed a program cycle the signal will be momentarily activated for a
period of approximately 10ms.
Pin #14 Machine Ready (Output):
- After machine power on, the signal will be activated.
- The signal will automatically switch off if any of the below conditions occur.
o “Machine Busy” Output signal activated.
o “End of Cycle” Output signal activated.
o “Alarm Out” Output signal activated.
- The signal will be re-activated automatically when all of the above conditions do not occur.