Input Signal Definition
Pin #3 CC Initialize (Input):
- When connected to a GND pin the “CC Initialize” signal will be activated, resulting in the machine
dispense cycle being actuated.
o When in “PURGE or “TEACH”
mode, the machine will continue to be actuated (i.e.
Dispensing fluid) until “CC Initialize” signal is removed from the GND pin.
o When in “TIMED” or “TIME+” mode, the machine will continue to be actuated (i.e. Dispensing
fluid) until the set dispense time on the machine has been reached.
o When in “CYCLE” mode, the machine will continue to be actuated (i.e. Dispensing fluid) in a
looping cycle until “CC Initialize” signal is removed from the GND pin and then re-applied.
- A green LED light will light up above the button on the front panel of the controller, to identify
the machine is actuating a dispense cycle (i.e. Dispensing fluid).
Pin #4 Alarm In (Input):
- When connected to a GND pin the “Alarm In” signal will be activated, resulting in the “Alarm Out”
signal (Pin #6) being activated automatically.
- A pop-up message “Input Alarm” will also be displayed on the home screen
- It will not be possible to actuate a new dispense cycle until the “Alarm In” signal has been de-activated
and the machine reset by pressing the button or momentarily (two (2) seconds) activating pin
#16 of the I/O input circuit.
Pin #8 Start Signal IN 24V+ (Input):
-
When connected to an external 24V+ power supply, the “Start Signal IN 24V+” signal will be
activated, resulting in the machine dispense cycle being actuated.
o
When in “PURGE” or “TEACH” mode, the machine will continue to be actuated (i.e.
Dispensing fluid) until “CC Initialize” signal is removed from the GND pin.
o When in “TIMED” or “TIME+” mode, the machine will continue to be actuated (i.e. Dispensing
fluid) until the set dispense time on the machine has been reached.
o When in “CYCLE” mode, the machine will continue to be actuated (i.e. Dispensing fluid) in a
looping cycle until “CC Initialize” signal is removed from the GND pin and then re-applied.
- A green LED light will light up above the button on the front panel of the controller, to identify
the machine is actuating a dispense cycle (i.e. Dispensing fluid).
PLEASE READ: For the “Start Signal IN 24V+” signal to work correctly, “Start IN GND
(0V)” (pin #9) must be connected to an external GND (0V)