DC100 MAX Digital Dispenser Operating Manual
© 2023 Fisnar - 67 - DC100 MAX Rev 4
Pin #16 Clear/Reset In (Input):
- When momentarily (two (2) seconds) connected to a GND pin the “Clear/Reset In” signal will be
activated, resulting in the machine being reset and/or error message being cleared.
- The machine will need to be reset after one or more of the following conditions have occurred.
o Glue Alarm function activated
o Pressure Alarm function activated
o Vacuum Alarm function activated
o Dispense Limit function activated
o Alarm IN signal activated
o End of Sequence completed
Pin #18, 19, 20 and 21 Bit Status In (Input):
- The status setting of pin #18 - #21 are used to create a binary value to set the program number that
the machine will automatically change to when the “Program Select” pin #25 signal is activated.
- When connected to a GND pin the “Bit Status” signal will be activated, resulting in its status changing.
o Activated = Bit Status High (1)
o Not Activated = Bit Status Low (0)
- The below table can be referenced, to set the correct program number according to the Bit Status.
Program
Number
Pin #18
Bit Status 0
Pin #19
Bit Status 1
Pin #20
Bit Status 2
Pin #21
Bit Status 3
1
0
0
0
0
2
1
0
0
0
3
0
1
0
0
4
1
1
0
0
5
0
0
1
0
6
1
0
0
1
7
0
1
1
0
8
1
1
1
0
9
0
0
0
1
10
1
0
0
1
11
0
1
0
1
12
1
1
0
1
13
0
0
1
1
14
1
0
1
1
15
0
1
1
1
16
1
1
1
1
Pin #16 Program Select In (Input):
- When momentarily connected to a GND pin, the “Program Select IN” signal will be activated, causing
the machine program number being changed according to the Bit Status of pin #18-21.