DC100 MAX Digital Dispenser Operating Manual
© 2023 Fisnar - 69 - DC100 MAX Rev 4
6.
The lower line of values on the display screen will change state (“1” to “0” or “0” to “1”) to confirm
the keypad button is working correctly or the machine I/O input is working correctly.
The values displayed from left to right are confirmed below
- 1
st
digit = Power button
- 2
nd
digit = Func. button
- 3
rd
digit = Mode button
- 4
th
digit = Set button
- 5
th
digit = Up Arrow button
- 6
th
digit = Down Arrow button
- 7
th
digit = Shot Button
- 8
th
digit = Contact Closure Initialize IN
- 9
th
digit = Alarm IN
- 10
th
digit = Start Signal IN
- 11
th
digit = Clear/Reset IN
- 12
th
digit = Bit 0 IN
- 13
th
digit = Bit 1 IN
- 14
th
digit = Bit 2 IN
- 15
th
digit = Bit 3 IN
- 16
th
digit = Program Select IN
- 17
th
digit = Foot Switch IN
7. To exit the I/O Test Screen remove the electrical power cord from the back of the machine.
8.
Reinsert the electrical power cord back the back of the machine and press the button.