6  Mounting
FLUXUS F502TE  6.3  Temperature probe
43
UMFLUXUS_F502TEV1-5EN, 2020-05-29
6.3.2.2 Installation with FLEXIM clasp
• Cut the tension strap to length (pipe circumference + at least 120 mm).
• Insert approx. 20 mm of the tension strap into the slot of the clasp (see Fig. 6.37).
• Bend the end of the tension strap.
• Position the temperature probe on the pipe (see Fig. 6.36).
• Place the tension strap around the temperature probe and the pipe. 
• Insert the tension strap through the parts (2) and (1) of the clasp.
• Pull the tension strap firmly and engage it in the inner hooks of the clasp.
• Tighten the screw of the clasp.
Fig. 6.35: Clasp
Fig. 6.36: Temperature probe on the pipe
Caution!
The edge of the tension strap is very sharp.
Risk of injury! 
→ Debur sharp edges. 
→ Wear the required personal protective equipment. 
→ Observe the applicable rules. 
Fig. 6.37: FLEXIM clasp
a b
(2)
(2)
(1)
(1)
(1)
(2)